Sign In | Join Free | My himfr.com
Home > IFM Pressure Sensor >

PI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agents

Xiamen ZhiCheng Automation Technology Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap PI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agents from wholesalers
     
    Buy cheap PI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agents from wholesalers
    • Buy cheap PI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agents from wholesalers
    • Buy cheap PI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agents from wholesalers
    • Buy cheap PI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agents from wholesalers

    PI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agents

    Ask Lasest Price
    Brand Name : IFM
    Model Number : PI1709
    Certification : 3C
    Price : 743$/piece
    Payment Terms : T/T
    Supply Ability : 1piece in stock
    Delivery Time : 3 day
    • Product Details
    • Company Profile

    PI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agents

    Product characteristics
    Number of inputs and outputsNumber of digital outputs: 1; Number of analogue outputs: 1
    Measuring rangePI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agents PI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agents PI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agents PI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agents-1...1 bar -1000...1000 mbar -14.5...14.5 psi -100...100 kPa
    Process connectionthreaded connection G 1 external thread Aseptoflex Vario
    Application
    Special featureGold-plated contacts
    Measuring elementceramic-capacitive pressure measuring cell
    Temperature monitoringno
    Applicationflush mountable for the food and beverage industry
    Mediaviscous media and liquids with suspended particles; liquids and gases
    Medium temperature [°C]-25...150
    Min. bursting pressure30000 mbar435 psi3000 kPa
    Pressure rating10000 mbar145 psi1000 kPa
    Vacuum resistance[mbar]-1000
    Type of pressurerelative pressure; vacuum
    No dead spaceyes
    MAWP (for applications
    according to CRN)
    [bar]10
    Electrical data
    Operating voltage [V]18...30 DC
    PI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agentsifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PM1709-01 — 31.07.2023 —
    PM1709
    Flush pressure sensor
    PM-1-1BREA01-E-ZVG/US
    Min. insulation resistance [MΩ]100; (500 V DC)
    Protection classIII
    Reverse polarity protectionyes
    Integrated watchdogyes
    2-wire
    Current consumption[mA]3.5...21.5
    Power-on delay time[s]1
    3-wire
    Current consumption[mA]< 45
    Power-on delay time[s]0.5
    Inputs / outputs
    Number of inputs and outputsNumber of digital outputs: 1; Number of analogue outputs: 1
    Outputs
    Total number of outputs2
    Output signalanalogue signal; IO-Link; (configurable)
    Number of digital outputs1; (IO-Link)
    Number of analogue outputs1
    Analogue current output [mA]4...20; (scalable)
    Max. load [Ω]700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA)
    Short-circuit proofyes
    Overload protectionyes
    Measuring/setting range
    Measuring range-1...1 bar-1000...1000 mbar-14.5...14.5 psi-100...100 kPa
    Analogue start point-1000...600 mbar-14.5...8.7 psi-100...60 kPa
    Analogue endpoint-600...1000 mbar-8.7...14.5 psi-60...100 kPa
    Insteps of1 mbar0.01 psi0.1 kPa
    Factory settingASP = -1000 mbarAEP = 1000 mbar
    Accuracy / deviations
    Repeatability [% of the span]< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
    Characteristics deviation
    [% of the span]
    < ± 0,2; (linearity incl. hysteresis and repeatability,
    limit value setting to DIN EN IEC 62828-1)
    Linearity deviation[% of the span]< ± 0,15; (Turn down 1:1)
    Hysteresis deviation< ± 0,15; (Turn down 1:1)
    [% of the span]
    Long-term stability
    [% of the span]
    < ± 0,1; (Turn down 1:1; per year)
    Total deviation over
    temperature range
    Temperature rangetotal deviation
    -25...15 °CCharacteristics deviation ± 0,05 % of the
    span / 10 K
    15...80 °CCharacteristics deviation
    80...150 °CCharacteristics deviation ± 0,1 % of the span /
    10 K
    Notes on the accuracy /
    deviation
    for further details see section Diagrams and graphs
    PI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agents ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PM1709-01 — 31.07.2023 —
    PM1709
    Flush pressure sensor
    PM-1-1BREA01-E-ZVG/US
    Response times
    Damping for the analogue [s]0...4
    output dAA
    2-wire
    Step response time analogue [ms]30
    output
    3-wire
    Step response time analogue [ms]7
    output
    Interfaces
    Communication interfaceIO-Link
    Transmission typeCOM2 (38,4 kBaud)
    IO-Link revision1.1
    SDCI standardIEC 61131-9
    ProfilesDigital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
    SIO modeno
    Required master port typeA
    Process data analogue3
    Min. process cycle time [ms]3.2
    IO-Link resolution pressure [mbar]0.5
    IO-Link functions (acyclical)application specific tag; internal temperature
    Supported DeviceIDsType of operationDeviceID
    default667
    Operating conditions
    Ambient temperature [°C]-25...80
    Storage temperature [°C]-40...100
    ProtectionIP 67; IP 68; IP 69K
    Tests / approvals
    EMCDIN EN 61000-6-2
    DIN EN 61000-6-3
    Shock resistanceDIN EN 60068-2-2750 g (11 ms)
    Vibration resistanceDIN EN 60068-2-620 g (10...2000 Hz)
    MTTF [years]323
    Note on approvalfactory certificate available as download at www.factory-certificate.ifm
    UL approvalUL Approval no.J021
    Mechanical data
    Weight[g]306.9
    Housingcylindrical
    Dimensions[mm]Ø 30.2 / L = 111
    Materialsstainless steel (316L/1.4404); PBT
    Materials (wetted parts)ceramics (99.9 % Al2O3); stainless steel (316L/1.4435);
    surface characteristics: Ra < 0,4 / Rz 4; PTFE
    Min. pressure cycles100 million
    Tightening torque[Nm]35
    Process connectionthreaded connection G 1 external thread Aseptoflex Vario
    PI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agentsifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PM1709-01 — 31.07.2023 —
    PM1709
    Flush pressure sensor
    PM-1-1BREA01-E-ZVG/US
    Remarks
    Pack quantity1 pcs.
    Electrical connection
    PI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agentsConnector: 1 x M12; coding: A; Contacts: gold-plated
    Connection
    PI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agents
    1 connection for 2-wire operation ( analogue )
    2 connection for 3-wire operation ( analogue / IO-Link )
    OUT1 : IO-Link
    OUT2 : analogue output
    PI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agentsifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — PM1709-01 — 31.07.2023 —
    PM1709
    Flush pressure sensor
    PM-1-1BREA01-E-ZVG/US
    Diagrams and graphs
    ambient temperature influence onPI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agentsX temperature
    Y total deviation
    the accuracy
    Quality PI1709 - Flush pressure sensor with display - ifm - ifm electronic Resistant to high-pressure cleaning with aggressive cleaning agents for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xiamen ZhiCheng Automation Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)