Sign In | Join Free | My himfr.com
Home > IFM Pressure Sensor >

IFM SV vortex flowmeters with display for water based media SV4200 SVR12XXXIRKG

Xiamen ZhiCheng Automation Technology Co., Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap IFM SV vortex flowmeters with display for water based media SV4200 SVR12XXXIRKG from wholesalers
     
    Buy cheap IFM SV vortex flowmeters with display for water based media SV4200 SVR12XXXIRKG from wholesalers
    • Buy cheap IFM SV vortex flowmeters with display for water based media SV4200 SVR12XXXIRKG from wholesalers
    • Buy cheap IFM SV vortex flowmeters with display for water based media SV4200 SVR12XXXIRKG from wholesalers
    • Buy cheap IFM SV vortex flowmeters with display for water based media SV4200 SVR12XXXIRKG from wholesalers

    IFM SV vortex flowmeters with display for water based media SV4200 SVR12XXXIRKG

    Ask Lasest Price
    Brand Name : IFM
    Model Number : SV4200
    Certification : 3C
    Price : $383/piece
    Payment Terms : T/T
    Supply Ability : 1piece in stock
    Delivery Time : 3 day
    • Product Details
    • Company Profile

    IFM SV vortex flowmeters with display for water based media SV4200 SVR12XXXIRKG

    Product characteristics
    Number of inputs and outputsNumber of digital outputs: 2
    Measuring range1...20 l/min0.06...1.2 m³/h
    Process connectionthreaded connection G 1/2 DN8
    Application
    Special featureGold-plated contacts
    Applicationfor industrial applications
    Mediawater; glycol solutions; coolants
    Medium temperature [°C]-10...90
    Pressure rating [bar]12
    IFM SV vortex flowmeters with display for water based media SV4200 SVR12XXXIRKGifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SV4200-00 — 02.02.2023 —
    SV4200
    Vortex flow meter with display
    SVR12XXXIRKG/US-100
    Pressure rating [Mpa]1.2
    Note on pressure ratingup to 40 °C
    MAWP (for applications [bar]3.9
    according to CRN)
    Electrical data
    Operating voltage[V]18...30 DC
    Current consumption[mA]< 30
    Min. insulation resistance[MΩ]100; (500 V DC)
    Protection classIII
    Reverse polarity protectionyes
    Power-on delay time[s]< 3
    Inputs / outputs
    Number of inputs and outputsNumber of digital outputs: 2
    Outputs
    Total number of outputs2
    Output signalswitching signal; frequency signal; IO-Link; (configurable)
    Electrical designPNP/NPN
    Number of digital outputs2
    Output functionnormally open / normally closed; (parameterisable)
    Max. voltage drop switching
    output DC
    [V]2.5
    Permanent current rating of
    switching output DC
    [mA]100
    Short-circuit protectionyes
    Overload protectionyes
    Measuring/setting range
    Measuring range1...20 l/min0.06...1.2 m³/h
    Display range0...24 l/min0...1.44 m³/h
    Resolution0.1 l/min0.005 m³/h
    Set point SP1.2...20 l/min0.07...1.2 m³/h
    Reset point rP1...19.8 l/min0.06...1.19 m³/h
    Frequency endpoint, FEP4...20 l/min0.24...1.2 m³/h
    Insteps of0.1 l/min0.005 m³/h
    Frequency at the endpoint [Hz]100...1000
    FRP
    Measuring dynamics1:20
    Temperature monitoring
    Measuring range[°C]-10...90
    Display range[°C]-30...110
    Resolution[°C]0.5
    Set point SP[°C]-9...90
    Reset point rP[°C]-10...89
    Insteps of[°C]0.5
    Frequency start point, FSP[°C]-10...70
    Frequency endpoint, FEP[°C]10...90
    IFM SV vortex flowmeters with display for water based media SV4200 SVR12XXXIRKGifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SV4200-00 — 02.02.2023 —
    SV4200
    Vortex flow meter with display
    SVR12XXXIRKG/US-100
    Frequency at the endpoint [Hz]100...1000
    FRP
    Accuracy / deviations
    Flow monitoring
    Accuracy (in the measuring
    range)
    ± 2 % MEW; (water)
    Repeatability± 0,5 % MEW
    Temperature monitoring
    Accuracy [K]± 1
    Response times
    Flow monitoring
    Response time[s]1; (dAP = 0)
    Damping process value dAP[s]0...5
    Temperature monitoring
    Dynamic response T05 / T09 [s]T09 = 6
    Software / programming
    Parameter setting optionshysteresis / window; normally open / normally closed; switching logic;
    frequency output; switch-on/switch-off delay; Damping; Display unit
    Interfaces
    Communication interfaceIO-Link
    Transmission typeCOM2 (38,4 kBaud)
    IO-Link revision1.1
    SDCI standardIEC 61131-9
    ProfilesSmart Sensor: Process Data Variable; Device Identification, Device Diagnosis
    SIO modeyes
    Required master port typeA
    Process data analogue2
    Process data binary2
    Min. process cycle time [ms]3
    Supported DeviceIDsType of operationDeviceID
    Default484
    Operating conditions
    Ambient temperature[°C]0...60
    Note on ambient temperaturemedium temperature < 80 °C
    medium temperature < 90 °C: 0...50 °C
    Storage temperature[°C]-20...80
    ProtectionIP 65; IP 67
    Tests / approvals
    EMCDIN EN 61000-6-2
    DIN EN 61000-6-3
    IFM SV vortex flowmeters with display for water based media SV4200 SVR12XXXIRKGifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SV4200-00 — 02.02.2023 —
    SV4200
    Vortex flow meter with display
    SVR12XXXIRKG/US-100
    CPA approvalmodel number001VO
    accuracy class-
    maximum allowable error± 2 % FS
    Q (min)0,09 m³/h
    Q (t)0,24 m³/h
    Q (max)1,2 m³/h
    Shock resistanceDIN EN 60068-2-275 g (11 ms)
    Vibration resistanceDIN EN 60068-2-6with water / 10...50 Hz 1 mm
    with water / 50...2000 Hz 2 g
    MTTF [years]342
    UL approvalUL Approval no.I001
    Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request
    Mechanical data
    Weight[g]474
    Materialsstainless steel (1.4404 / 316L); PC; PBT+PC-GF30; PPS; TPE-U
    Materials (wetted parts)stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM
    Tightening torque[Nm]30
    Process connectionthreaded connection G 1/2 DN8
    Remarks
    RemarksMW = measured value
    MEW = Final value of the measuring range
    Pack quantity1 pcs.
    Electrical connection
    Connector: 1 x M12; coding: A; Contacts: gold-plated
    IFM SV vortex flowmeters with display for water based media SV4200 SVR12XXXIRKGifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SV4200-00 — 02.02.2023 —
    SV4200
    Vortex flow meter with display
    SVR12XXXIRKG/US-100
    Connection
    IFM SV vortex flowmeters with display for water based media SV4200 SVR12XXXIRKG
    OUT1: Flow monitoring
    - switching output
    - frequency output
    - IO-Link
    OUT2: flow monitoring and temperature monitoring
    - switching output
    - frequency output
    colours to DIN EN 60947-5-2
    Core colours :
    BK = black
    BN = brown
    BU = blue
    WH = white
    Diagrams and graphs
    Pressure lossIFM SV vortex flowmeters with display for water based media SV4200 SVR12XXXIRKGdP Pressure loss
    Q volumetric flow quantity
    IFM SV vortex flowmeters with display for water based media SV4200 SVR12XXXIRKGifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SV4200-00 — 02.02.2023 —
    SV4200
    Vortex flow meter with display
    SVR12XXXIRKG/US-100
    pressure rating (bar)IFM SV vortex flowmeters with display for water based media SV4200 SVR12XXXIRKG
    Quality IFM SV vortex flowmeters with display for water based media SV4200 SVR12XXXIRKG for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Xiamen ZhiCheng Automation Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)