Product characteristics | ||||||||||
Number of inputs and outputs | Number of digital outputs: 2 | |||||||||
Measuring range | 1...20 l/min | 0.06...1.2 m³/h | ||||||||
Process connection | threaded connection G 1/2 DN8 | |||||||||
Application | ||||||||||
Special feature | Gold-plated contacts | |||||||||
Application | for industrial applications | |||||||||
Media | water; glycol solutions; coolants | |||||||||
Medium temperature [°C] | -10...90 | |||||||||
Pressure rating [bar] | 12 | |||||||||
![]() | ||||||||||
SV4200 | ||||||||||
Vortex flow meter with display | ||||||||||
SVR12XXXIRKG/US-100 | ||||||||||
Pressure rating [Mpa] | 1.2 | |||||||||
Note on pressure rating | up to 40 °C | |||||||||
MAWP (for applications [bar] | 3.9 | |||||||||
according to CRN) | ||||||||||
Electrical data | ||||||||||
Operating voltage | [V] | 18...30 DC | ||||||||
Current consumption | [mA] | < 30 | ||||||||
Min. insulation resistance | [MΩ] | 100; (500 V DC) | ||||||||
Protection class | III | |||||||||
Reverse polarity protection | yes | |||||||||
Power-on delay time | [s] | < 3 | ||||||||
Inputs / outputs | ||||||||||
Number of inputs and outputs | Number of digital outputs: 2 | |||||||||
Outputs | ||||||||||
Total number of outputs | 2 | |||||||||
Output signal | switching signal; frequency signal; IO-Link; (configurable) | |||||||||
Electrical design | PNP/NPN | |||||||||
Number of digital outputs | 2 | |||||||||
Output function | normally open / normally closed; (parameterisable) | |||||||||
Max. voltage drop switching output DC | [V] | 2.5 | ||||||||
Permanent current rating of switching output DC | [mA] | 100 | ||||||||
Short-circuit protection | yes | |||||||||
Overload protection | yes | |||||||||
Measuring/setting range | ||||||||||
Measuring range | 1...20 l/min | 0.06...1.2 m³/h | ||||||||
Display range | 0...24 l/min | 0...1.44 m³/h | ||||||||
Resolution | 0.1 l/min | 0.005 m³/h | ||||||||
Set point SP | 1.2...20 l/min | 0.07...1.2 m³/h | ||||||||
Reset point rP | 1...19.8 l/min | 0.06...1.19 m³/h | ||||||||
Frequency endpoint, FEP | 4...20 l/min | 0.24...1.2 m³/h | ||||||||
Insteps of | 0.1 l/min | 0.005 m³/h | ||||||||
Frequency at the endpoint [Hz] | 100.. | .1000 | ||||||||
FRP | ||||||||||
Measuring dynamics | 1:20 | |||||||||
Temperature monitoring | ||||||||||
Measuring range | [°C] | -10...90 | ||||||||
Display range | [°C] | -30...110 | ||||||||
Resolution | [°C] | 0.5 | ||||||||
Set point SP | [°C] | -9...90 | ||||||||
Reset point rP | [°C] | -10...89 | ||||||||
Insteps of | [°C] | 0.5 | ||||||||
Frequency start point, FSP | [°C] | -10...70 | ||||||||
Frequency endpoint, FEP | [°C] | 10...90 | ||||||||
![]() | ||||||||||
SV4200 | ||||||||||
Vortex flow meter with display | ||||||||||
SVR12XXXIRKG/US-100 | ||||||||||
Frequency at the endpoint [Hz] | 100...1000 | |||||||||
FRP | ||||||||||
Accuracy / deviations Flow monitoring | ||||||||||
Accuracy (in the measuring range) | ± 2 % MEW; (water) | |||||||||
Repeatability | ± 0,5 % MEW | |||||||||
Temperature monitoring | ||||||||||
Accuracy [K] | ± 1 | |||||||||
Response times Flow monitoring | ||||||||||
Response time | [s] | 1; (dAP = 0) | ||||||||
Damping process value dAP | [s] | 0...5 | ||||||||
Temperature monitoring | ||||||||||
Dynamic response T05 / T09 [s] | T09 = 6 | |||||||||
Software / programming | ||||||||||
Parameter setting options | hysteresis / window; normally open / normally closed; switching
logic; frequency output; switch-on/switch-off delay; Damping; Display unit | |||||||||
Interfaces | ||||||||||
Communication interface | IO-Link | |||||||||
Transmission type | COM2 (38,4 kBaud) | |||||||||
IO-Link revision | 1.1 | |||||||||
SDCI standard | IEC 61131-9 | |||||||||
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | |||||||||
SIO mode | yes | |||||||||
Required master port type | A | |||||||||
Process data analogue | 2 | |||||||||
Process data binary | 2 | |||||||||
Min. process cycle time [ms] | 3 | |||||||||
Supported DeviceIDs | Type of operation | DeviceID | ||||||||
Default | 484 | |||||||||
Operating conditions | ||||||||||
Ambient temperature | [°C] | 0...60 | ||||||||
Note on ambient temperature | medium temperature < 80 °C | |||||||||
medium temperature < 90 °C: 0...50 °C | ||||||||||
Storage temperature | [°C] | -20...80 | ||||||||
Protection | IP 65; IP 67 | |||||||||
Tests / approvals | ||||||||||
EMC | DIN EN 61000-6-2 | |||||||||
DIN EN 61000-6-3 | ||||||||||
![]() | ||||||||||
SV4200 | ||||||||||
Vortex flow meter with display | ||||||||||
SVR12XXXIRKG/US-100 | ||||||||||
CPA approval | model number | 001VO | ||||||||
accuracy class | - | |||||||||
maximum allowable error | ± 2 % FS | |||||||||
Q (min) | 0,09 m³/h | |||||||||
Q (t) | 0,24 m³/h | |||||||||
Q (max) | 1,2 m³/h | |||||||||
Shock resistance | DIN EN 60068-2-27 | 5 g (11 ms) | ||||||||
Vibration resistance | DIN EN 60068-2-6 | with water / 10...50 Hz 1 mm | ||||||||
with water / 50...2000 Hz 2 g | ||||||||||
MTTF [years] | 342 | |||||||||
UL approval | UL Approval no. | I001 | ||||||||
Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request | |||||||||
Mechanical data | ||||||||||
Weight | [g] | 474 | ||||||||
Materials | stainless steel (1.4404 / 316L); PC; PBT+PC-GF30; PPS; TPE-U | |||||||||
Materials (wetted parts) | stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM | |||||||||
Tightening torque | [Nm] | 30 | ||||||||
Process connection | threaded connection G 1/2 DN8 | |||||||||
Remarks | ||||||||||
Remarks | MW = measured value | |||||||||
MEW = Final value of the measuring range | ||||||||||
Pack quantity | 1 pcs. | |||||||||
Electrical connection | ||||||||||
Connector: 1 x M12; coding: A; Contacts: gold-plated | ||||||||||
![]() | ||||||||||
SV4200 | ||||||||||
Vortex flow meter with display | ||||||||||
SVR12XXXIRKG/US-100 | ||||||||||
Connection | ||||||||||
![]() | ||||||||||
OUT1: Flow monitoring - switching output - frequency output - IO-Link | ||||||||||
OUT2: flow monitoring and temperature monitoring - switching output - frequency output | ||||||||||
colours to DIN EN 60947-5-2 Core colours : | ||||||||||
BK = black BN = brown BU = blue WH = white | ||||||||||
Diagrams and graphs | ||||||||||
Pressure loss | ![]() Q volumetric flow quantity | |||||||||
![]() | ||||||||||
SV4200 | ||||||||||
Vortex flow meter with display | ||||||||||
SVR12XXXIRKG/US-100 | ||||||||||
pressure rating (bar) | ![]() |
![]() |